Get a complete and prolonged look at of the anatomical structure by means of panoramic imaging coupled with velocity indication and ahead/backward scan capability earning scanning less of a challenge, smoother and more controllable.

one.two.2 Warning Labels Warning Labels Meaning Please cautiously look at this manual before use product. The subsequent labels are a. Never spot the device over a sloped area. Normally the accessible if the system product may possibly slide, causing individual harm or maybe the unit works Together with the cell malfunction.

Evaluating individuals in currently’s demanding natural environment needs ground breaking know-how that permits clinicians for making fast and confident diagnoses. The flexibility of your DP-fifty expands your clinical utility while assisting to make improvements to affected individual care.

The person is not really permitted to open the handles and panel of the procedure, neither Observe: unit disassemble is allowed. To ensure the method performance and safety, only Mindray engineers or engineers authorized by Mindray can accomplish servicing.

Permits usage of multiple scanned angles to kind one image, causing Improved contrast resolution and improved visualization

Cut off cable ties connecting the leading device over the Show by diagonal cutting pliers, and after that pull out the corresponding cable plugs.

Find much better diagnostic facts via prolonged view in the anatomical construction on all linear probes

The DP-fifty Expert is surely an impressive, superior-overall performance Ultrasound Technique engineered to help you get the insights you'll need. The Program’s strong engine and higher-pace processing provide excellent graphic quality and a complete information and facts management Answer.

Operate: About the back-stop of the key board, a Distinctive monitor IC is made use of to watch sign voltages  and clock battery electric power which have been furnished to the principle board by the key device box power source module.

iZoom™ enables accurate viewing of image from distance iWorks™ Protocol assists standardize workflow and decrease exam times

Cookies are essential to the proper functioning of a website. To increase your knowledge, we use cookies to remember log-in specifics and supply secure log-in, acquire stats to optimize internet site features, and provide content material tailored to your pursuits.

NOTE: Before inserting the connector in to the probe port, inspect the connector pin. When the pin is bent, never utilize the probe until finally it's been inspected / fixed / replaced. Setting up Peripherals With the versions on the supported peripherals, please make reference to “two.

After replacing the CPU module, critical file should be produced Again according to the new MAC tackle and prepared into HDD of the equipment. Or else, the configuration purpose on the product is going to be missing. Immediately after taking away the CPU module, Remove panhead screws with washers (12 M3X6) set on the principle device box, you will take from the board. Web page 118 Determine eight-29 Disassemble the Control Panel Assembly (1) Keep the upper fringe of user interface assembly, and open up up the user interface. Determine eight-30 Disassemble the User interface Assembly (two) After taking away a person countersunk head self-tapping screw PT3X10 fixed on the user interface and get out the plug from the keyboard and the principle device connecting cables, you could potentially get rid of the control panel assembly.

Efficiency Check 5.five.1 Check Method Resolution Detection depth Geometric Position Precision Blackout location exam Record the Examination illustrations or photos 5.5.2 Examination Material The graphic employed here is just for reference, stick with the picture impact in the actual Notice: scenario. Needs: Exhibit: established the contrast and brightness in the scientific software benefit (or the default status) Operation natural environment: dim home, simulating the scientific software environment. Webpage 76 In issue which the transverse resolution screening targets are horizontally shown, history the nominal length of two targets that could be clearly regarded. Repeat the operation higher than to the transverse resolution tests targets at other depths. As shown in determine below. Axial resolution ... Website page 77 When utilizing the convex probe, keep the transverse resolution tests targets to NOTE: be displayed close to the midline. When utilizing a linear probe with steer purpose, do not turn on the steer purpose when execute the transverse resolution exam. Zoom from the location the place the targets located if necessary. The diameter on the focus on position at a particular depth is equivalent to the transverse resolution for the depth. Web site 78 five.

Click Agree and Proceed to accept cookies and go on to the site or click More details to determine comprehensive descriptions of the types of cookies and pick out no matter if to simply accept particular cookies even though on the location.

NOTE: Be sure that you might pull out and thrust in the IO board sockets vertically when pulling out and assembling the IO board assembly about the placement on the take care of. Take away panhead screws with Dp50rb login washers M3X6 (4) used to protected the IO board, after which you can you could potentially choose out the IO board. Web site 116 Clear away panhead screws with washers (2 M3X6) which might be preset on the leading unit, take out the higher baffle after which pull out two cables connecting the most crucial board to the power module assembly.